Asbestos – Australia

Select the RPE

The following information is from the Safe Work Australia Model Code of Practice “How to safety remove asbestos (July 2020)“. If your local state/territory requirements are different, please use the non-preloaded form section to enter your specific required respiratory protection.

 
Work procedure Required respirator Filter type
Non-Friable: Simple enclosure erection for containing undamaged asbestos materials to prevent damage—no direct handling but possible disturbance of asbestos Disposable, half-face particulate respirators
OR
Half-face, particulate filter (cartridge) respirator
P1 or P2
Non-Friable: Inspection of the condition of any installed friable asbestos, which appears in poor condition or has been disturbed Disposable, half-face particulate respirators
OR
Half-face, particulate filter (cartridge) respirator
P1 or P2
Non-Friable: Sampling material for the purpose of identifying asbestos Disposable, half-face particulate respirators
OR
Half-face, particulate filter (cartridge) respirator
P1 or P2
Non-Friable: Removal of non-friable asbestos (e.g. asbestos cement sheets, ceiling tiles and vinyl tiles) Disposable, half-face particulate respirators
OR
Half-face, particulate filter (cartridge) respirator
P1 or P2
Friable: Extensive sample operations on friable asbestos Full-face, particulate filter (cartridge) respirator P3
Friable: Maintenance work involving the removal of small quantities of friable asbestos (e.g. replacement of friable asbestos gaskets and insulation) Full-face, particulate filter (cartridge) respirator P3
Friable: Certain forms of wet stripping in which wetting is prolonged and effective, and certain small-scale dry stripping operations Full-face, powered air-purifying particulate respirator
OR
Full-face, positive pressure demand air-line respirator
P3
Friable: Certain forms of dry stripping and ineffective wet stripping (light wetting, no time given to saturate) Full-face, powered air-purifying particulate respirator
OR
Full-face, positive pressure demand air-line respirator
No lesser respirator will suffice
P3
Friable: Dry stripping in confined areas Full suit or hood, positive pressure demand continuous flow air-line respirator
No lesser respirator will suffice
P3 only as a backup